Requirements on the ultrasonic open channel flowmeter installation

Some requirements on the ultrasonic open channel flowmeter installation

 

If you are interested in ultrasonic open channel flow meter, please feel free to contact with us via cindy@metern.cn or WhatsApp: 008613614080180

 

Ultrasonic flowmeters measure the level in a channel by transmitting a pulse of sound from the face of the sensor to the surface of the flow stream and measuring the time for the echo to return.  The transit time corresponds to the distance between the face of the sensor and the surface of the water.  

 

When the meter is initially set up, a predetermined distance (or level in some meters) is set. This distance is either 
the zero level (no flow present) or a specific level in  the flume or weir.  With this initial calibration it is only 

a matter of simple arithmetic to determine the liquid level.  This level is then applied to either pre-programmed discharge 
equations or strapping tables to output a flow rate.

 

Because the sensor is not in contact with the water, ultrasonic sensors have no scheduled maintenance.  

Ultrasonic sensors are not affected by chemicals, grease,  suspended solids, or silt in the flow stream. 

Some necessary setting must be done before measurement, please be noted below:

 

1) Max_Dist

Refers to distance from the zero water level to sensor. After the completion of the installation,please enter the 

correct  empty distance here.



2) Min level and Max level must be setted based on parshall plume code. 


 

Starting effective level and the highest effective level of the measurement of instantaneous

flow, when the liquid level is less than the effective initial level value, instantaneous flow is as 0, when the liquid 

level is greater than the highest effective level value, then  the corresponding flow to the highest effective level 

values is as the instantaneous flow. Unit:mm.

 

 

3) The instrument probe should be installed in the upstream position 0.5m ~ 1m distance to the weir plate.

 

4) Blink: refers to the distance which could not be measured from the bottom of the sensor which is decided 

by the characteristics of the sensor. It has been set as 30-50 cm before leaving factory.