Measuring Principle | Electromagnetic |
Product headline | The sensor with degree of protection IP68 (Type 6P enclosure) and a modular electronic concept. The specialist in the water and wastewater industry for the most demanding applications. |
Sensor features | Secure, reliable long‐term operation – robust and completely welded sensor. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). |
Transmitter features | Fast commissioning – application‐specific Quick Setups. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. |
Nominal diameter range |
DN 25...2000 1"...78" |
Max. measured error |
±0.5% ±0.2% (optional) |
Measuring range | 0...110'000 m3/h |
Max. process pressure |
PN6...40 Cl 150...300 JIS 10...20K AWWA Class D AS 2129 Table E AS 4087 PN16 |
Medium temperature range |
-20...+80°C (-4...+176°F) |
Ambient temperature range |
-20...+60°C -40...+60°C (optional) |
Degree of protection |
IP 67 (NEMA 4x) IP 68 (Nema 6P) |
Display/Operation |
Two line display with backlit Push button |
Outputs |
4...20 mA Pulse/Frequency Status |
Inputs | Status |
Digital communication |
HART PROFIBUS PA/DP |
Hazardous area approvals |
ATEX FM CSA |