Medium | Liquid, Gas, Steam |
Nominal Diameter | DN15…DN400 |
Medium Temperature | -50~+500℃ |
Nominal Pressure | 1.6Mpa, 2.5Mpa, 4.0Mpa, Higher pressure can be customized. |
Range ability |
Normal range 1:10 Extended range 1:15 |
Accuracy |
Liquid: ±1.0% reading Gas, Steam: ±1.5% reading |
Repeatability | ≤1/3 accuracy |
Power Supply |
Pulse output: 12VDC, 24VDC 4-20mA: 24VDC Local display: built in 3.6V lithium battery, working life >2 years |
Output Signal |
Pulse frequency signal 0.1…3000Hz (low level≤1V, high level≥6V) Two-wire 4-20mA.DC current signal (HART is available) Three-wire 4-20mA.DC current signal (RS485 is available) |
Ambient |
Ambient temperature: Normal -30…60℃, Ex-proof -20…50℃, Local display -10…50℃ Ambient humidity: relatively humidity 5%...85% Atmospheric pressure: (86…106)Kpa |
Allowed vibration acceleration | Capacitive≤1.0g |
Signal Transmitting distance |
Pulse≤500m 4-20mA≤1000m RS485≤1200m |
Electrical interface | M20x1.5 |
Ex-proof |
Flame proof: ExdIIBT5 Intrinsic safety: ExiaIICT5 |
Protection level | IP65, IP68 |
Housing Material | 1Cr18Ni9Ti (available for other material) |
Nominal Diameter | Flow range (m3/h) | ||
Liquid | Gas | Steam | |
25 | 0.9-9 | 9.5-95 | 9.5-95 |
40 | 2.3-23 | 22-220 | 22-220 |
50 | 3.5-35 | 32-320 | 32-320 |
65 | 6-60 | 60-600 | 60-600 |
80 | 9-90 | 78-780 | 78-780 |
100 | 14-140 | 105-1050 | 105-1050 |
125 | 22-220 | 220-2200 | 220-2200 |
150 | 32-320 | 300-3000 | 300-3000 |
200 | 56-560 | 560-5600 | 560-5600 |
250 | 90-900 | 900-9000 | 900-9000 |
300 | 130-1300 | 1300-13000 | 1300-13000 |