Home > Products > >
MTCMF Sanitary coriolis mass flow meter
MTCMF Sanitary coriolis mass flow meter
Name: MTCMF Sanitary coriolis mass flow meter
Size: DN3~DN200
Accuracy: 0.1%~0.5%
Structure: Integral type and Split type
Output: Pulse, 4~20mA, RS485
Communication: Modbus,Hart
Ex-proof: Ex (ia) ⅡC T6Gb
Description

MTCMF Sanitary coriolis mass flow meter

Overview

Metern MTCMF Coriolis mass flowmeters are the leading precision flow and density measurement solution offering the most accurate and repeatable mass measurement for liquids, or slurries. MTCMF meters offer the most accurate measurement available for virtually any process fluid, while exhibiting exceptionally low pressure drop.



Ultimate real world performance

Unchallengeable MTCMF performance on liquid mass flow, volume flow, and density measurement
Unique design delivers unparalleled measurement sensitivity and stability
Guarantees consistent, reliable performance over the widest flow range
Designed to minimize process, mounting, and environmental effect



Superior performance in the most challenging applications


Low Flow Precision Measurement Precision Measurement & Process Control High Capacity Precision Measurement
Flavoring
Vials
Chemical injection
Kg/min – tons/hr
Truck loading
Internal allocation
Leak detection
Produced fluids with chlorides
Up to 3,200 tons/hr
Custody transfer
Ship loading
Railcar loading
Pipeline measurement
Marine bunkering
Feedstock and fuel blending


Liquid flow rates

Model Nominal Size (mm) Flow rate (t/hr)
MTCMF-003 3 0~0.18
MTCMF-006 6 0~0.56~0.7
MTCMF-008 8 0~0.96~1.2
MTCMF-010 10 0~1.8~2.1
MTCMF-015 15 0~3.6~4.5 
MTCMF-020 20 0~6~7.2
MTCMF-025 25 0~9.6~12
MTCMF-032 32 0~18~21
MTCMF-040 40 0~30~36
MTCMF-050 50 0~48~60
MTCMF-080 80 0~150~180
MTCMF-100 100 0~240~280
MTCMF-150 150 0~480~600


Performance specifications for sensor
Accuracy: ±0.1~0.5%
Repeatability: ±0.1~0.25%
Density measurement range: 0.5~2g/cm3, Accuracy: ±0.002 g/cm3
Operating temperature: -50~+200℃(standard),  -200~+350℃
Ambient temperature: -40~+60℃  or  -20~+55℃
The measuring tube material: SS316L; The housing material: SS304
Nominal pressure: 4.0MPa(standard), 35MPa, High pressure can be customized.
Ex-proof: Exd (ia)ⅡC T6Gb



Performance specifications for transmitter

FT-521 Transmitter
LED local display
Display variable: mass flow, volume flow, density,
Ambient temperature: -40~+60℃ 
Output signal: Pulse+4~20mA+RS485
Communication: Modbus
Power supply: 18~36VDC power≤7W; 85~265VAC power: 10W
Protection level: IP67
Ex-proof: Exd (ia)ⅡC T6Gb


FT-522 Transmitter
LCD local display
Display variable: mass flow, volume flow, density, temperature
Ambient temperature: -20~+60℃
Output signal: Pulse+4~20mA+RS485
Communication: Modbus
Power supply: 18~36VDC power≤7W; 85~265VAC power: 10W
Protection level: IP67
Ex-proof: Exd (ia)ⅡC T6Gb