MTCMF Sanitary coriolis mass flow meter
Overview
Metern MTCMF Coriolis mass flowmeters are the leading precision flow and density measurement solution offering the most accurate and repeatable mass measurement for liquids, or slurries. MTCMF meters offer the most accurate measurement available for virtually any process fluid, while exhibiting exceptionally low pressure drop.
Ultimate real world performance
Unchallengeable MTCMF performance on liquid mass flow, volume flow, and density measurement
Unique design delivers unparalleled measurement sensitivity and stability
Guarantees consistent, reliable performance over the widest flow range
Designed to minimize process, mounting, and environmental effect
Superior performance in the most challenging applications
Low Flow Precision Measurement |
Precision Measurement & Process Control |
High Capacity Precision Measurement |
Flavoring
Vials
Chemical injection |
Kg/min – tons/hr
Truck loading
Internal allocation
Leak detection
Produced fluids with chlorides |
Up to 3,200 tons/hr
Custody transfer
Ship loading
Railcar loading
Pipeline measurement
Marine bunkering
Feedstock and fuel blending |
Liquid flow rates
Model |
Nominal Size (mm) |
Flow rate (t/hr) |
MTCMF-003 |
3 |
0~0.18 |
MTCMF-006 |
6 |
0~0.56~0.7 |
MTCMF-008 |
8 |
0~0.96~1.2 |
MTCMF-010 |
10 |
0~1.8~2.1 |
MTCMF-015 |
15 |
0~3.6~4.5 |
MTCMF-020 |
20 |
0~6~7.2 |
MTCMF-025 |
25 |
0~9.6~12 |
MTCMF-032 |
32 |
0~18~21 |
MTCMF-040 |
40 |
0~30~36 |
MTCMF-050 |
50 |
0~48~60 |
MTCMF-080 |
80 |
0~150~180 |
MTCMF-100 |
100 |
0~240~280 |
MTCMF-150 |
150 |
0~480~600 |
Performance specifications for sensor
Accuracy: ±0.1~0.5%
Repeatability: ±0.1~0.25%
Density measurement range: 0.5~2g/cm3, Accuracy: ±0.002 g/cm3
Operating temperature: -50~+200℃(standard), -200~+350℃
Ambient temperature: -40~+60℃ or -20~+55℃
The measuring tube material: SS316L; The housing material: SS304
Nominal pressure: 4.0MPa(standard), 35MPa, High pressure can be customized.
Ex-proof: Exd (ia)ⅡC T6Gb
Performance specifications for transmitter
FT-521 Transmitter
LED local display
Display variable: mass flow, volume flow, density,
Ambient temperature: -40~+60℃
Output signal: Pulse+4~20mA+RS485/Hart 7
Communication: Modbus
Power supply: 18~36VDC power≤7W; 85~265VAC power: 10W
Protection level: IP67
Ex-proof: Exd (ia)ⅡC T6Gb
FT-522 Transmitter
LCD local display
Display variable: mass flow, volume flow, density, temperature
Ambient temperature: -20~+60℃
Output signal: Pulse+4~20mA+RS485/Hart 7
Communication: Modbus
Power supply: 18~36VDC power≤7W; 85~265VAC power: 10W
Protection level: IP67
Ex-proof: Exd (ia)ⅡC T6Gb