40E Coriolis flowmeter
40E Coriolis flowmeter
Name: 40E Coriolis flowmeter
The flowmeter for minimized cost of ownership combined with a compact field transmitter
Description
Measuring Principle Coriolis
Product headline The flowmeter for minimized cost of ownership combined with a compact field transmitter. Highly accurate measurement of liquids and gases for a wide range of standard applications.
Sensor features Cost-effective – multi-purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, temp). Space-saving installation – no in/outlet run needs. Compact dual-tube system. Medium temperature up to +140 °C (+284°F).
Transmitter features Cost-effective – dedicated design for low-end applications and direct integration. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2-line backlit display without local operation. Device in compact version.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, volume flow, corrected volume flow
Max. measured error Mass flow (liquid): ±0.5 %
Volume flow (liquid): ±0.5 %
Mass flow (gas): ±1.0 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180 000 kg/h (0 to 6600 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –40 to +140 °C (–40 to +284 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material Powder-coated die-cast aluminium
Degree of protection IP67, type 4X enclosure
Display/Operation 2-line backlit display without push buttons (direct integration)
Configuration via operating tools possible
Outputs 3 outputs:
0-20 mA (active)/4-20 mA (active/passive)
Pulse/frequency/switch output (passive)
Inputs Status input
Digital communication HART
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI, TIIS
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, marine
PED, CRN
3A