83I Coriolis flowmeter
83I Coriolis flowmeter
Name: 83I Coriolis flowmeter
Combines in-line viscosity and flow measurement with extended transmitter functionality
Description

Measuring Principle Coriolis
Product headline Combines in‐line viscosity and flow measurement with extended transmitter functionality. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
Sensor features Energy‐saving – full bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Straight, easy cleanable single‐tube system. TMB® technology.
Transmitter features Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: Titanium grade 9
Connection: Titanium grade 2
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
Max. measured error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180 000 kg/h (0 to 6600 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –50 to +150 °C (–58 to +302 °F)
Ambient temperature range Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast
Degree of protection IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Outputs 4 modular outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive)
Relay
Inputs 2 modular inputs:
Status
0‐20 mA (active)/4‐20 mA (active/passive)
Digital communication HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
Power supply DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals ATEX, IECEx, FM, CSA, NEPSI, TIIS
Other approvals and certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL
PED, CRN
3A, EHEDG