Measuring Principle | Coriolis |
Product headline | The flowmeter with premium accuracy, robustness and extended transmitter functionality. Highest measurement performance for liquids and gases under varying, demanding process conditions. |
Sensor features | Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measured error ±0,05 % (PremiumCal). Rated secondary containment up to 40 bar (580 psi). |
Transmitter features | Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Device in compact or remote version. |
Nominal diameter range |
DN 8 to 250 (⅜ to 10") High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") |
Wetted materials |
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. measured error |
Mass flow (liquid): ±0.1 % (standard), 0.05 % (option) Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range |
Standard: –50 to +200 °C (–58 to +392 °F) High temperature: –50 to +350 °C (–58 to +662 °F) |
Ambient temperature range |
Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
Transmitter housing material |
Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
Display/Operation |
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs |
4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) Relay |
Inputs |
2 modular inputs: Status 0‐20 mA (active)/4‐20 mA (active/passive) |
Digital communication | HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP |
Power supply |
DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI, TIIS |
Other approvals and certificates |
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine PED, CRN, AD 2000 3A, EHEDG, FDA NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK |