Measuring Principle | Coriolis |
Product headline | The single‐tube flowmeter for smallest flow quantities with a compact or remote transmitter. Measuring accurately smallest quantities of liquids and gases for continuous process control. |
Sensor features | Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). |
Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. |
Nominal diameter range | DN 1 to 4 (¹⁄₂₄to ¹⁄₈") |
Wetted materials |
Measuring tube: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022) Connection: 1.4539 (904L); Alloy C22, 2.4602 (UNS N06022); 1.4404 (316/316L) |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
Max. measured error |
Mass flow (liquid): ±0.15 % Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | to 450 kg/h (0 to 16.5 lb/min) |
Max. process pressure | PN 40, Class 300, 20K, 400 bar (5800 psi) |
Medium temperature range | –50 to +200 °C (–58 to +392 °F) |
Ambient temperature range |
Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material |
Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
Display/Operation |
2‐line backlit display with push buttons Configuration via local display and operating tools possible |
Outputs |
3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) |
Inputs | Status input |
Digital communication |
HART PROFIBUS PA |
Power supply |
DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI, TIIS |
Other approvals and certificates |
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL CRN 3A, EHEDG |