Measuring Principle | Coriolis |
Product headline | The straight single‐tube flowmeter with a compact or remote transmitter. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment. |
Sensor features | Energy‐saving – full bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Straight, easy cleanable single‐tube system. TMB® technology. |
Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version. |
Nominal diameter range | DN 8 to 80 (⅜ to 3") |
Wetted materials |
Measuring tube: Titanium grade 9 Connection: Titanium grade 2 |
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
Max. measured error |
Mass flow (liquid): ±0.15 % Volume flow (liquid): ±0.15 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³ |
Measuring range | 0 to 180 000 kg/h (0 to 6600 lb/min) |
Max. process pressure | PN 100, Class 600, 63K |
Medium temperature range | –50 to +150 °C (–58 to +302 °F) |
Ambient temperature range |
Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant |
Transmitter housing material |
Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast |
Degree of protection | IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure |
Display/Operation |
2‐line backlit display with push buttons Configuration via local display and operating tools possible |
Outputs |
3 outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) |
Inputs | Status input |
Digital communication |
HART PROFIBUS PA |
Power supply |
DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz) |
Hazardous area approvals | ATEX, IECEx, FM, CSA, NEPSI, TIIS |
Other approvals and certificates |
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL PED, CRN 3A, EHEDG |