Measuring Principle | Hydrostatic |
Characteristic |
Digital transmitter with capacitive sensor and ceramic membrane Modular transmitter Long term stability Enhanced safety via self diagnostic functions Secondary process barrier |
Supply voltage |
4...20mA HART 10,5...45V DC (Non Ex): Ex ia: 10,5...30V DC PROFIBUS PA: 9...32 V DC (Non Ex) FOUNDATION Fieldbus: 9...32 V DC (Non Ex) |
Reference Accuracy |
Standard: 0.05% Platinum: up to 0.025% |
Long term stability | 0,05% of URL/year |
Process temperature |
-20°C...150°C (-4°F...257°F) |
Ambient temperature |
-40°C...85°C (-40°F...185°F) |
Measuring cell |
100mbar...40bar (1.5psi...600psi) relative/ absolute |
Smallest calibratable span | 25 mbar (3.63 psi) rel./ abs. |
Vacuum resistance | 0 mbar abs. |
Max. Turn down | 100:1 |
Max. overpressure limit | 60bar (900psi) |
Process connection |
Thread: G1/2...G2, R1/2, MNPT1/2...MNPT2 Flange: DN25...DN80, ASME 1"...4", JIS 10K |
Hygienic |
Tri-Clamp DIN11851 Varivent N SMS DRD |
Material process membrane | Ceramic |
Material gasket | Viton, EPDM, Chemraz, Kalrez, NBR |
Fill fluid | none, dry measuring cell |
Material housing |
Die-cast aluminum, AISI 316L |
Output |
4...20mA HART PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals |
ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI Overfill prevention WHG SIL EN10204-3.1 3A, EHEDG GL/ ABS Marine NSF Drinking water |
Options |
HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing |
Specialities | Diagnostic functions |